![Kohzu Precision RC-010 Manual Download Page 30](http://html1.mh-extra.com/html/kohzu-precision/rc-010/rc-010_manual_1990247030.webp)
SC-021/RC-010 Introduction Manual /Practical Version
26
ⅰ
)
Change setting item number to
“No.35”
at
System Setting Status
by moving dial-key or down.
ⅲ
)
Using the keypad and the sample formula below, enter the coefficient for the speed level
. The result
will be the actual maximum drive speed.
ⅳ
)
Press “
SET
” button again when finished.
ⅱ
)
Press “
SET
” button to access
data entry screen
.
2.
Manually Setting the Drive Speed
《
Rewriting of Speed Tables 1 to 9 (SP1 to SP9)
》
System Setting Item 35
<Relation between speed table and operating speed>
Maximum speed of speed table
x
Coefficient of speed table
=
Actual drive maximum speed
SP1
:
2,000
[pps]
SP2
:
3,000
[pps]
SP3
:
4,000
[pps]
SP4
:
5,000
[pps]
SP5
:
6,000
[pps]
SP6
:
7,000
[pps]
SP7
:
8,000
[pps]
SP8
:
9,000
[pps]
SP9
:
10,000
[pps]
SP1
:
40,000
[pps]
SP2
:
60,000
[pps]
SP3
:
80,000
[pps]
SP4
:
100,000
[pps]
SP5
:
120,000
[pps]
SP6
:
140,000
[pps]
SP7
:
160,000
[pps]
SP8
:
180,000
[pps]
SP9
:
200,000
[pps]
x
=
20
(Enter a single
coefficient
from 1 to 300)
<Example of setting>
This process allows operator to rewrite the default speed setting for the entire Speed Table (SP1
through SP9) simultaneously by using a single coefficient.