![Kohzu Precision RC-010 Manual Download Page 33](http://html1.mh-extra.com/html/kohzu-precision/rc-010/rc-010_manual_1990247033.webp)
SC-021/RC-010 Introduction Manual /Practical Version
29
Md
PE
Ax
Sp
Val
T O P S P E E D ( p p s )
0 2
:
1
0 0 0 0 5 0 0 0
Md
PE
Ax
Sp
Val
T O P S P E E D ( p p s )
0 2
:
1
N N N N N N N N
Md
PE
Ax
Sp
Val
S T A R T S P E E D ( p p s )
0 1
:
1
0 0 0 0 0 5 0 0
Md
PE
Ax
Sp
Val
T O P S P E E D ( p p s )
0 2
:
1
0 0 0 0 5 0 0 0
(B) Setting the Maximum Speed for Speed Table SP0. (
System Setting Item 2)
ⅰ
)
Change setting item number to
“No.2”
at
System Setting Status
by moving dial-key up or down.
ⅱ
)
Press “
SET
” button to access
data entry screen
.
ⅲ
)
Using the keypad, enter the desired maximum speed.
ⅳ
)
Press “
SET
” button again when finished.
Dial-key moving up or down
Press ”SET”
Press ”SET”
Fix the setting
Change setting item
number
Into data entry
screen
Enter Start
Speed
Enter Start Speed