![Kohzu Precision RC-010 Manual Download Page 32](http://html1.mh-extra.com/html/kohzu-precision/rc-010/rc-010_manual_1990247032.webp)
SC-021/RC-010 Introduction Manual /Practical Version
28
ⅲ)
Using the keypad, enter the desired start speed.
ⅳ)
Press “
SET
” button again when finished.
Md
PE
Ax
Sp
Val
S T A R T S P E E D ( p p s )
0 1
:
1 0
0
0
0
0 5 0 0
Md
PE
Ax
Sp
Val
S T A R T S P E E D ( p p s )
0 1
:
1 N
N
N
N
N N N N
Dial-key moving up or down
Md
PE
Ax
Sp
Val
S P D T A B L E 1 - 3 0 0
3 5
:
1
0 0 1
Md
PE
Ax
Sp
Val
S T A R T S P E E D ( p p s )
0 1
:
1 0
0
0
0
0 5 0 0
Press ”SET”
Fix the setting
Enter Start
Speed
Change setting item
number
Into data entry
screen
Enter Start Speed
Press ”SET”
《
Rewriting of Speed Table 0 (SP0)
》
System Setting Items 1&2
(A) Setting the Start Speed for Speed Table SP0.
(System Setting Item 1)
ⅰ
)
Change setting item number to
“No.1”
at
System Setting Status
by moving dial-key up or down.
ⅱ
)
Press “
SET
” button to access
data entry screen
.
This process allows operator to rewrite starting and maximum speeds for Speed Table 0.