11.23
Section 11
Reassembly
11
Figure 11-81. Adjusting Governor Lever.
4. Insert a nail into the hole on the cross shaft and
rotate the shaft
counterclockwise
as far as it will
turn, then torque the hex nut to
6.8 N·m
(60 in. lb.)
. See Figure 11-82.
Figure 11-82. Holding and Tightening Governor Arm.
5. Reconnect the lead wire to the fuel shut-off
solenoid if so equipped.
Install Throttle & Choke Controls
1. Connect the choke linkage to the carburetor and
choke actuator lever. See Figure 11-83.
Figure 11-83. Connecting Choke Linkage.
2. Mount the main control bracket, and air cleaner
support bracket (if used) to the cylinder heads
using the four hex flange screws. Torque the
screws to
10.7 N·m (95 in. lb.)
into new holes, or
7.3 N·m (65 in. lb.)
into used holes. See Figure
11-84.
Figure 11-84. Torquing Main Control Bracket.
2. Make sure the throttle linkage is connected to the
governor lever and the throttle lever on the
carburetor.
3. Move the governor lever
toward
the carburetor
as far as it will go (wide-open throttle) and hold
in position. See Figure 11-81.