- 16 -
3. Threshold
Threshold (L1, L2) setting, hysteresis (H1, H2) setting, and reference import ΔL setting configuration, and checking of the threshold value
for the reference import mode
Setting channel selection
[
L1]
Select using
△
or
▽
.
CH Setting channel lights
CH1: Channel 1
CH2: Channel 2
CH3: Channel 3
CH4: Channel 4
ALL: Simultaneous
setting of channels 1
through 4
(Sensor head settings
can only be configured
simultaneously for all
channels.)
SEQU: Sequential setting
of channels 1 through 4
[Allowable Input Range]
L1, L2: Sensor display range
(Initial default: -50.6)
H1, H2: 0 to maximum absolute
value of the sensor display range
(Initial default: 0.2)
Δ
L: ± Maximum absolute value of
the sensor display range
(Initial default: 1.0)
Configures the L1
threshold value setting.
[
L2]
Select using
△
or
▽
.
Configures the L2
threshold value setting.
[
H1]
Select using
△
or
▽
.
Configures the H1
hysteresis setting.
[
H2]
Select using
△
or
▽
.
Configures the H2
hysteresis setting.
[
dL]
Select using
△
or
▽
.
Configures the
Δ
L
reference import setting.
[
Reference]
Select using
△
or
▽
.
Performs reference import.
[
Lr]
Displays the threshold
value for reference input
(Lr).
Returns to:
SW
■■■■
Setting value input
CH Setting channel lights
SW
■■■■
Setting channel selection
When reference import
ends normally.
When reference input
generates an error.
CH Execution channel lights
CH1: Channel 1
CH2: Channel 2
CH3: Channel 3
CH4: Channel 4
ALL: Batch setting of
channels 1 through 4
Returns to:
SW
■■■■
Set value display
CH Display channel lights
Select a channel
using
△
or
▽
.
SW
■■■■
CH Normal completion channel lights
SW
■■■■
Returns to:
Returns to:
CH Normal completion channel lights
SW Error generating channel lights
button
button
button
button
button
button
button
button
button
button
※※※
※※※
※
※