- 18 -
6. External Input
External input function assignment
Setting channel selection
SW
■■■■
CH
■■■■
CH1: Channel 1
CH2: Channel 2
CH3: Channel 3
CH4: Channel 4
ALL: Simultaneous setting
of channels 1 through 4
SEQU: Sequential setting
of channels 1 through 4
oFF: External input not used
rEF: Reference import execution
Adj
:
Zero adjustment execution
Returns to:
External input function assignment selection
CH Setting channel lights
SW
■■■■
button
button
button
※
7. Hold
Hold input function assignment
Setting channel selection
SW
■■■■
CH
■■■■
CH1: Channel 1
CH2: Channel 2
CH3: Channel 3
CH4: Channel 4
ALL: Simultaneous setting
of channels 1 through 4
SEQU: Sequential setting
of channels 1 through 4
oFF: Hold OFF
PH: Peak hold
bH: Bottom hold
Returns to:
External input function assignment selection
CH Setting channel lights
SW
■■■■
• Hold setting is canceled (Hold OFF) following power off.
button
button
button
※
8. Adjust
Zero adjustment execution, zero adjustment clear, zero adjustment retention setting
Setting channel selection
[
Adjust]
Select using
△
or
▽
.
CH Setting channel lights
CH1: Channel 1
CH2: Channel 2
CH3: Channel 3
CH4: Channel 4
ALL: Batch setting of channels 1 through 4
Executes zero adjustment.
Returns to:
Returns to:
Returns to:
SW
■■■■
Displayed 1 second.
Setting channel selection
[
Adjust Clear]
CH Setting channel lights
CH1: Channel 1
CH2: Channel 2
CH3: Channel 3
CH4: Channel 4
ALL: Batch setting of channels 1 through 4
Clears zero adjustment.
SW
■■■■
Displayed 1 second.
Select using
△
or
▽
.
Zero adjustment retention setting selection
[
Adjust Save]
oFF: Zero adjustment not retained when power is turned off
on: Zero adjustment retained even when power
Configures the zero
adjustment retention setting.
SW
■■■■
CH
■■■■
button
button
button
button
button
button
button
※
※