A-61662 April 2010
3-13
Custom Functions
— allows you to set a function for the
F1
and
F2
buttons on the control panel. Available options are:
•
None
: no function will be performed when F1/F2 is pressed.
•
Feed Test Batch
: activates the Test
feed mode which is used to test
and verify the scanner’s feeding capabilities and allows you to feed
transport cleaning sheets. This is the default setting for the F1 key.
•
Page Eject
: will activate the transport to eject multi-fed documents or
clear the transport after a stop. This is the default setting for the F2
key.
•
Clean Print Head
: if you have the optional imprinter installed, will
activate the imprinter to clean the print head.
Audio
— allows you to set the volume of a selected sound that alerts
you to an error.
•
Volume
: can be set to
Mute, Low, Medium
or
High
.
•
Error Sound
: one of three sounds can be selected:
Sound1
,
Sound2
,
Sound3
. Click
Play Sound
to hear the currently active
error sound.
Advanced
— when you click
Advanced
, the Advanced Settings
screen will be displayed.
From this screen, you can adjust the image boundaries or borders of a
scanned image which is determined by autocrop. Each side of a
scanned image can be individually adjusted by cropping or adding extra
black border. This only affects images as part of the scanning process.
This adjustment cannot be made to an existing image.
The range of adjustment is between -0.500 to 0.500 inches; negative
values crop, and positive values add extra border. The default values
are 0.000 for all sides
.
When finished, click
Save
to save your changes and close the
Advanced Settings window.