background image

 

 

RANGEVISION

 

Setup and calibration

 

NEO   

 

Summary of Contents for NEO

Page 1: ...RANGEVISION Setup and calibration NEO...

Page 2: ...Package contents 5 Installing software and drivers 6 Setting up with computer for work with the scanner Connecting projector 7 Configuring computer parameters 8 Scanner assembly 9 Calibrating the scan...

Page 3: ...the procedures for preparing the scanner installing the required drivers calibration procedure scanning procedure and tips for acquiring high quality three dimensional object model Information may be...

Page 4: ...ocessor Intel Core i3 i5 1 8 GHz and better graphics card with HDMI output RAM Not less than 8 GB 2 USB ports 4 Model NEO Camera resolution 2 Mpix Diagonal of the matrix 1 3 Texture scanning yes FOV 3...

Page 5: ...n plate and a stand for the calibration plate which are used to calibrate the scanner 5 Name qty 1 Scanning module Mounting structure with projector 1 Cable kit for PC connection USB HDMI 1 2 Tripod 1...

Page 6: ...esired language type and path for installation After the files have been copied install drivers and graphics libraries necessary for the correct operation of RangeVision 3D scanner If you have access...

Page 7: ...ctor First connect the USB to power up the projector and then connect it to the HDMI port of your video card After connecting the projector it should be displayed in the system If the computer has sev...

Page 8: ...recurrence of the problems during the scanner operation you must turn off the screensaver and sleep mode Go to Screen Saver Settings menu and turn off the screen saver disable turning off the display...

Page 9: ...nning module onto the tripod 2 Connect USB cable to your PC 3 Connect HDMI cable to your PC 4 When using the turntable connect it to the power source then connect the USB cable to your PC and turn the...

Page 10: ...turntable finding the table axis Full and automatic calibrations are used before work with the scanner after transporting the scanner Fast calibration is used if you suspect that the camera moved due...

Page 11: ...own list choose the correct calibration plate size specified on the b ack side of the plate or add a new one It is possible that camera images in the software will be swapped or flipped from the start...

Page 12: ...cameras matches the markers on the plate the cross is projected on the central marker 3 If the plate placement is incorrect an error message will appear Correct the placement and repeat the step In c...

Page 13: ...tance from the center of the plate to the scanner when turning the plate The exception are only snapshots in positions 10 and 11 do not rotate the plate at a very high angle Ensure that all marks on t...

Page 14: ...uring orienting starts to be very different from the original one you need to re calibrate the equipment Example The initial accuracy is 0 084 accuracy after orientation is 0 25 The value exceeded 0 2...

Page 15: ...wn to the right is in compliance with Waste Electrical and Electronic Equipment Directive 2002 96 EC WEEE The mark indicates the requirement NOT to dispose the equipment as unsorted municipal waste bu...

Reviews: