4
.
Take out the MOTOR.
5
.
Install the new MOTOR.
FUNCTION TEST
1
.
Check that the FILM PICK UP MOTOR M6 is running.
Start the SERVICE PROGRAM
Select SERVICE MODE from the GLOBAL MENU ......................... press ENTER
ENTER SERVICE MODE MESSAGE IS DISPLAYED .................. press ENTER
UNIT DATA are displayed ..................................................................... press ENTER
Select COMPONENT TEST ................................................................... press ENTER
Select CASSETTE MOTORS ................................................................... press ENTER
Select FILM PICK UP M6 ...................................................................... press ENTER
Select forward ............................................................................................. press ENTER
Select backward ........................................................................................... press ENTER
2
.
Exit the SERVICE PROGRAM
Press BACKSPACE 3 times
Select LEAVE COMPONENT TEST .................................................... press ENTER
Select Quit ML2000 SERVICE MODE ................................................. press ENTER
Select Quit the program ........................................................................... press ENTER.
1
2
3
4
5
6
7
8
9
CONNECTOR X60
MOTOR CABLE
YELLOW
BLUE
RED
MOUNTING SCREW (3)
MOTOR M6
figure 2-29
SM 3477
REPLACEMENTS
KODAK AG, Stuttgart
2-31