5
.
Adjust R38 to 1.93V
±
40 mV, while the motor is running.
6
.
Disconnect the DVM.
7
.
Exit the SERVICE MODE.
Press BACKSPACE 3 times
Select LEAVE COMPONENT TEST press ENTER
Select QUIT ML2000 SERVICE MODE press ENTER
Select Quit the program press ENTER
RECEIVING MAGAZINE INTERFACE (ML2000 only)
STEPPER MOTOR INTERFACE M13/M_PI
PURPOSE:
To adjust the phase current of M13 to the correct value. If this current is too low M13 will not
run correctly. If this current is too high the POWER AMPLIFIERS U43 and U44 on CIRCUIT
BOARD A4 sheet 4 will become overloaded.
1
.
Start STEPPER MOTOR PROCESSOR INTERFACE.
Start the SERVICE PROGRAM
Select SERVICE MODE from the GLOBAL MENU ......................... press ENTER
ENTER SERVICE MODE MESSAGE is displayed ............................ press ENTER
R38
TP 15
TP 11
figure 3-44
ADJUSTMENTS
SM 3477
6/97
3-44
KODAK AG, Stuttgart