6
.
Disconnect the DVM.
7
.
Stop the STEPPER MOTOR.
Select MOTOR OFF
8
.
Exit the SERVICE MODE.
Press BACKSPACE 3 times
Select LEAVE COMPONENT TEST ..................................................... press ENTER
Select QUIT ML2000 SERVICE MODE ............................................... press ENTER
Select Quit the program ............................................................................ press ENTER
RECEIVING MAGAZINE (ML2000 only)
SENSOR B24/C_RM_E RECEIVING MAGAZINE ENTRANCE
SENSOR B25/C_RM_F RECEIVING MAGAZINE FULL
PURPOSE
SENSOR B24 checks if a FILM is fully in the RECEIVING MAGAZINE
SENSOR B25 checks if the RECEIVING MAGAZINE is full (approx. 120 FILMS)
NOTE
To avoid film fogging in the RECEIVING MAGAZINE, SENSORS B24 and B25 are not part of the
SENSOR TEST. Both SENSORS can only be adjusted after they have been enabled via the COM-
PONENT TEST - RECEIVE MAG. SENSORS. The ADJUSTMENT PROCEDURE is the same for
both SENSORS.
1
.
Switch off the ML2000.
2
.
Take off the PANELS.
3
.
Take out the RECEIVING MAGAZINE and empty it.
4
.
Take out the RECEIVING MAGAZINE TUNNEL, disconnect the SENSORS and lay
down the RECEIVING MAGAZINE TUNNEL on the floor.
5
.
Connect the SENSORS with the EXTENSION CABLE (stored in the PNEUMATIC
chamber) to the ML2000.
6
.
Insert an empty RECEIVING MAGAZINE into the RECEIVING MAGAZINE TUNNEL.
7
.
Switch on the ML2000.
8
.
Connect the LAP TOP COMPUTER and start the RECEIVING MAGAZINE SENSORS.
Start the SERVICE PROGRAM
Select SERVICE MODE from the GLOBAL MENU .......................... press ENTER
ENTER SERVICE MODE MESSAGE is displayed ............................ press ENTER
Select COMPONENT TEST from the MAIN MENU ........................ press ENTER
Select RECEIVE MAG. SENSORS ........................................................ press ENTER
Select TEST ON
9
.
Loosen the 2 horizontal SENSOR MOUNTING SCREWS and manually move the
SENSOR from fully left to fully right. On both sides the SENSOR LED will turn red. Set
the SENSOR to the mid position and fasten the horizontal MOUNTING SCREWS. See
the drawing on the next page.
10.
Loosen the 2 vertical SENSOR MOUNTING SCREWS and manually move the
SENSOR fully up and down. On both sides the SENSOR LED will turn red. Set the
SENSOR to the mid position and fasten the vertical MOUNTING SCREWS.
SM 3477
ADJUSTMENTS
KODAK AG, Stuttgart
3-47