UNIT DATA are displayed....................................................................... press ENTER
Select COMPONENT TEST from the MAIN MENU ........................ press ENTER
Select MAGAZINE MOTORS................................................................. press ENTER
Select MAGAZINE OPENING M14...................................................... press ENTER
Select FORWARD
Select BACKWARD
Select FORWARD
3
.
Check if all magazines are fully opened.
4
.
If necessary readjust the position of the SENSOR B36/M_OP_EO.
5
.
Make sure that the MAGAZINE LIDS do not touch the MAGAZINE HOLDER above.
6
.
Close the MAGAZINES.
Select BACKWARD
7
.
If necessary readjust the position of the SENSOR B37/M_OP_EC.
8
.
Exit the SERVICE MODE.
Press BACKSPACE 3 times
Select LEAVE COMPONENT TEST ..................................................... press ENTER
Select QUIT ML2000 SERVICE MODE ............................................. press ENTER
Select Quit the program ........................................................................... press ENTER
9
.
Reload the MAGAZINES.
MOTOR M14
SENSOR B36
SENSOR B37
MOUNTING SCREWS
figure 3-42
ADJUSTMENTS
SM 3477
6/97
3-42
KODAK AG, Stuttgart