A-61580 November 2007
3-37
Sensors
— three sensors cover the width of the paper path. In order for
multi-fed documents to be detected correctly, they must pass under one
of these sensors.
•
Left, Middle, Right:
this allows you to select which sensor(s) you
want turned on. For example, if you know that the left side of the
document has a “sticky” note on it, you can turn off the left sensor.
Length Detection
— allows you to select the maximum length of the
documents in your job set. If the scanner detects a document of that
length or longer, it will determine that a multifeed has occurred. You can
turn this option off, or set a length of up to
34.5
inches.
Action When Detected
—
select what action you want the scanner to
take when a multifeed is detected. With all options, the scanner will
beep (if the scanner volume is on) and the condition will be logged in
the scanner.
•
Stop Scanning
: scanning will stop and control will return to the
scanning application (i.e., ends the job). Verify that the paper path
has been cleared and restart the scan session from the scanning
application.
•
Continue Scanning
: the scanner will continue to scan.
•
Pause Scanning
: scanning will stop but the scanning application will
be waiting for additional images (i.e., stops the feeder). Scanning
may be resumed by touching
Resume
on the touchscreen. Scanning
may be stopped by touching
End
Job
on the touchscreen or via the
scanning application.
Play sound on PC
— turn this option on if you want the PC to make a
sound when a multifeed is detected. You can click the
Browse
button to
select the desired .wav file.
NOTE: The sound on the PC may not occur at the exact time the
multifeed is detected by the scanner.