KODAK
1200i WIDE-FORMAT PRINTING SYSTEM
Technical Training Guide
44
Where:
2 = <color> Bottle Error – Pri CRC Failed!
3 = <color> Bottle Error – Sec CRC Failed!
4 = <color> Bottle Error – No Response!
5 = <color> Bottle Error – Write Protected!
6 = <color> Bottle Error – Copy Failed!
7 = <color> Bottle Error – MAC Mismatch!
Translation: The ID-chip or its connection is faulty.
These communication error messages are displayed in the “Bottle Info”
secondary menu. This display menu is made visible by pressing the associated
bottle color button (F1-F6).
INK K: BLACK QiD
MFGl X-X-XXX
OEM: 1
XXXXXXXXXXXXX
Bottle ID-chip errors are virtually identical when compared to the cartridge errors Type 1
and 2 explained above. There is no Type 3 classification for bottle ID-chips. In most
cases, the recommended error recovery procedure is to replace the bottle identified on
the display. This may be done prior to AND during a print job. If an error occurs during a
print job, the user has 30 seconds to find a replacement bottle and swap out the
identified stall before the print job is automatically paused.
Note: if a bottle is missing, a bottle error will occur, but if a bottle is missing, bottle chip is
missing or bottle chip is not making contact with the ID housing (within intermediate
reservoir) then an alarm condition will typically not be displayed as an initial screen
message on the control panel display. To access more information about bottle errors
press the MORE INFO key where the error will be specified. Below is a possible error
message:
An error condition will be displayed as:
K: ERROR*
***
Another unique error message is a programming problem with the ID chip and therefore
the bottle/chip will need to be replaced:
[<color>] MAC – MISMATCH ERROR
1. For all bottle errors except for the ‘mismatch
error’ check ID housing position (vertical and
horizontal alignment). The housing screw may
need to be loosened (T7 star-head screw) to
readjust the housing position slightly to enable
better contact.