KODAK
1200i WIDE-FORMAT PRINTING SYSTEM
Technical Training Guide
11
Step 5:
Raise Printer
- Using a four (4) person lift gently raise printer to the standing position.
Step 6:
Voltage Configuration
(for dryer system)
Prior to powering on printer ensure the voltage selector
switch is set to either 115V or 230V depending on line
source.
NOTE 1:
The voltage selector ships in the 230V
position.
NOTE 2:
the circuit beaker will ‘pop’ out in an over-
current condition and will need to be replaced if this
occurs.
Step 7:
Reservoir Installation
When installing the six (6) ink bottles ensure each bottle is
installed straight up and down to avoid damaging pins at
intermediate reservoir (located at base).
Firmware Note:
C1 = C
L
M1 = M
L
Note:
wait 5 minutes prior to
conducting line filling operation (using
‘Pump On’ from the control panel or
ink line may not fill properly.
NOTE:
during normal operation you will have only 30 seconds to change ink
bottles during print operations or a printer STOP error will occur.