KODAK
1200i WIDE-FORMAT PRINTING SYSTEM
Technical Training Guide
39
6. If cartridge recovery is not possible then proceed to replace the cartridge (cartridge
may have an internal air leak which is causing the ink pressure integrity problem).
The alarm message will be cleared when you send a new print job or power cycle the
printer. The steps involved to clear the alarm without a power cycle are:
1 - cancel the print job at the host
2 - navigate to the keypad main menu and press RESET
3 - navigate to the alarm display by pressing ALARM
4 - press the MORE INFO key
5 - determine the offending cartridge
6 - access carriage and replace offending cartridge
7 - access carriage back to home position
8 - send a new print job to clear the alarm (a prime printing test or calibration plot will
clear the alarm)
Example 2: <color> PEN ERROR – OVERCURRENT CARTRIDGE SHUTDOWN!
A cartridge OVERCURRENT error indicates the detection of an electrical short internal
to the cartridge –
the cartridge must be replaced
. This error is often the result of not
correcting a MAX INK TEMP. EXCEEDED error as described in Example 1 above.
All OVERCURRENT cartridge errors require replacement of the cartridge and recycling
of the printer power. The steps involved to restart the printer and replace the cartridge
are:
1 - cancel the print job at the host
2 - press the MORE INFO key on the keypad display to show
which cartridge is defective
3 - turn the printer power OFF
4 - replace the defective cartridge
5 - turn the printer power ON
For the following error message (examples):
Internal error shutdown
Image Manager
VFIRE VALUE=1
RETRY=3
or values may change…
Internal error shutdown
Image Manager
VFIRE VALUE=5
RETRY=0
If newer firmware is loaded (i.e. >2.01) and the error message remains, then the
carriage board
is likely faulty. Replace carriage board to correct symptom.
Example 3: <color> Pen Error – Invalid Pen ID!
The message indicates that the ID of the cartridge itself is not correct or is not
being read. This could be a contact problem between the cartridge and the carriage flex
or it could be that the cartridge ID is not correct or missing. You can verify this condition