A-61560 January 2007
Diagnostics - Debug tab
The Debug tab allows you to store the communications between the
scanner and a scanning application to a file that can be reviewed later.
In addition, the resulting images (both before and after image
processing has been done) can be saved.
Logging
— saves the communications between the scanner and a
scanning application to a file for later review. Click the drop-down box to
select from
Off
(the default),
On
or
Custom
. It is suggested that you do
not use the Custom setting unless directed to do so by Kodak support
personnel.
Flag
— by default, this is 1. Leave the flag at 1 unless instructed to use
another value by Kodak support personnel.
Filter
— captures only those items in the scanner to the application
communication stream desired and filters out anything else. Options
are x, y and z.
Images
- Received From Scanner
— normally, it is not necessary to
save the images received from the scanner before your selected image
processing options are applied. Use this checkbox when instructed by
Kodak support personnel.
•
Save
: click this checkbox to save raw images from the scanner
(before image processing is applied).
•
File prefix:
use a relevant file prefix to more easily find and sort the
saved images.
Raw
is the default.
•
Held in memory:
determines the number of images to save before
the images are overwritten. Normally, only one or two are needed.
Adjust as necessary.