6
7.3.
U
SAGE EXAMPLE
(M
ODBUS
TCP) ........................................................................................................... 128
7.4.
U
SAGE EXAMPLE
(M
ODBUS
RTU) .......................................................................................................... 129
7.5.
M
ODBUS
S
LAVE EXAMPLES
.................................................................................................................... 130
7.6.
M
ODBUS WORKING WITH SEVERAL SLAVES ON THE SAME
RS485
CONNECTION
..................................... 133
6.
BACNETIP INTERCONNECTION WITH LM2 ...................................................................................... 136
7.
ENOCEAN INTERCONNECTION WITH REACTOR ........................................................................... 138
7.1.
E
N
O
CEAN INTERFACES
........................................................................................................................... 138
7.2.
E
N
O
CEANTO
KNX
MAPPING
................................................................................................................... 138
7.3.
KNX
TO
E
N
O
CEAN MAPPING
.................................................................................................................. 140
8.
DMX INTERCONNECTION WITH LM2 ................................................................................................. 142
8.1.
E
XAMPLES
.............................................................................................................................................. 144
9.
3GMODEM CONNECTION WITH LM2 .................................................................................................. 146
9.1.
E
XAMPLES
.............................................................................................................................................. 146
9.2.
SMS
HANDLER PROGRAM
....................................................................................................................... 146
9.3.
S
END
SMS
MESSAGES TO SPECIFIC
SIM
NUMBERS AFTER GROUP
-
READ OR GROUP
-
WRITE IS TRIGGERED
148
10.
HDL PROTOCOL INTEGRATION IN LOGIC MACHINE 3 ................................................................ 150
10.1.
HDL
FUNCTION
....................................................................................................................................... 150
10.2.
U
SAGE EXAMPLE
–
HDL
DIMMER CONTROL
........................................................................................... 152
10.3.
U
SAGE EXAMPLE
–
HDL
RELAY CONTROL
.............................................................................................. 152
11.
COMMUNICATION WITH RS232/RS485 SERIAL PORTS .................................................................. 154
12.
OBJECT VALUE EXPORT VIA XML ...................................................................................................... 156
12.1.
A
LERTS
,
E
RRORS VALUES
....................................................................................................................... 158
13.
READ ALERTS RSS FEEDS FROM LOGIC MACHINE ....................................................................... 159
Summary of Contents for LogicMachine3 Re:actor
Page 10: ...10 Terminal connection schemes KNX TP...
Page 12: ...12 24V power supply...
Page 13: ...13 Analog inputs e g reed contact...
Page 14: ...14 Analog inputs 0 10V...
Page 15: ...15 Digital output...
Page 16: ...16 Resistive sensor input...
Page 17: ...17 Analog output...
Page 26: ...26 Make sure that bus status is Online press button in ETS...
Page 35: ...35 o Then minimize side bar by pressing on left arrow icon to make the map more visible...
Page 83: ...83 66 if err then 67 alert FTP upload failed s err 68 end...
Page 107: ...107...
Page 108: ...108 1 14 Help Documentation for scripting syntaxes is displayed in Help tab...
Page 126: ...126 Datapoints can be shown also in a way of table which can be later exported as CSV file...
Page 141: ...141...