KNIGHT D-SERIES SERVO HOIST OPERATION MANUAL
SECTION 5
SOFTWARE
88
Step 43.
Press the “SLOW ZONE SETUP” button on the HOIST CONFIGURATION INDEX screen.
Figure 5-67
Slow Zone Mode screen: (Refer to Figure 5-67)
Row #1) The Slow Zone Enabled Indicator. Green = ON, Red = OFF
The Vertical ‘VISUALIZATION’ bar shows the set Slow Zones in yellow and will change
depending on if the hoist is loaded or unloaded.
NOTE: Only one of the four buttons on this row can be active at a time.
The ‘SLOW ZONE DISABLE’ will turn off all Slow Zone Functions.
The ‘SLOW MOVING DOWN’ will activate Slow Zone functions while moving in a downward
direction based upon the hoist’s loaded/unloaded conditions and their corresponding
position setpoints.
The ‘SLOW MOVING UP’ will activate Slow Zone functions while moving in an upward
direction based upon the hoist’s loaded/unloaded conditions and their corresponding
position setpoints.
The ‘SLOW MOVING DOWN/UP’ will activate Slow Zone functions while moving in either
direction based upon the hoist’s loaded/unloaded conditions and their corresponding
position setpoints.
Row #2) The ‘INVERT ZONE’ inverts the function of the Slow Zone position. Normal operation will
activate Slow Zone below the position setpoint. If Slow Zone Invert is on then Slow Zone
Functions apply above the setpoints instead of below.
The ‘SLOW ZONE PART LOADED WEIGHT (LB)’ display shows the weight setpoint that that
determines the Part Loaded condition. This allows switching between different speeds
based upon weight, typically with the unloaded speeds being faster.
The ‘SLOW ZONE ENTRY DECEL (IPS^2)’ The maximum deceleration that will be used
when entering an active Slow Zone.