Step 12.
Press the “CAN’T MOVE” button on the TROUBLESHOOTING INDEX screen.
Figure 5-36
Can’t Move Up screen: (Refer to Figure 5-36)
Row #1) The ‘LIFT MODE NOT ACTIVE’ indicator will change to ‘LIFT MODE ACTIVE’ when
Lift Mode is active.
The ‘FLOAT MODE NOT ACTIVE’ indicator will change to ‘FLOAT MODE ACTIVE’ when
Float Mode is active.
Row #2) The ‘TOTAL WEIGHT (LB)’ display shows the total weight on the shackle of the inline handle.
The ‘ACTIVE UP STOP WEIGHT (LB)’ display shows the weight at which an up stop will
activate.
Row #3) The ‘CURRENT POSITION (IN)’ display shows the hoist’s current position.
The ‘ACTIVE UPPER LIMIT (IN)’ display shows the set upper limit that the hoist can move to.
Row #4) The ‘LIFT LC VOLTAGE (V)’ Display shows the live voltage reading of the lift load cell tied
to the handle.
The ‘FLOAT LC VOLTAGE (V)’ display shows the live voltage reading of the float load cell
tied to the shackle.
Row #5) Various Up Stop conditions are displayed. Red = ON, Green = OFF.
Buttons) Press the ‘BACK TO INDEX’ button to return to the TROUBLESHOOTING INDEX screen.