73
Specifications
ProLine P5*100 Isolation
Across Input and Output/Power Supply
Test voltage
18 kV AC
Type test
16 kV AC
100 % routine test
Partial discharge extinction
voltage
> 8 kV AC
10 pC
Rated isolation voltage
Basic insulation
Overvoltage category OV3,
pollution degree PD3
EN 50124-1, IEC 62497-1,
EN 50123-1, EN 50178
Max.
4800 V AC/DC
Rated impulse voltage: 33 kV
UL 347
P51100
P52100
3600 V AC/DC
4800 V AC/DC
Rated impulse voltage: 30 kV
Rated impulse voltage: 33 kV
Rated isolation voltage
Protection against
electric shock by
reinforced insulation
Overvoltage category OV3,
pollution degree PD3
for EN 50178: PD2
EN 50124-1, IEC 62497,
EN 50178
Max.
3600 V AC/DC
Rated impulse voltage: 33 kV
Contact protection
(protection against
electric shock)
Max.
3600 V AC/DC
with ZU 1030 protective covers,
ZU 1031 cable support sleeves
acc. to EN 50153 ranges I to III
Clearances
Min. 60 mm
Creepage distances
Min. 90 mm
CTI 600, insulant group I
acc. to EN 50123-1, EN 50124-1
ProLine P5*000 Isolation
Across Input and Output/Power Supply
Test voltage
12 kV AC
Type test
10 kV AC
100 % routine test
Partial discharge extinction
voltage
> 6 kV AC
10 pC
Rated isolation voltage
Basic insulation
Overvoltage category OV3,
pollution degree PD3
EN 50124-1, IEC 62497-1,
EN 50123-1,
EN 50178, UL 347
Max.
2000 V AC/DC
Rated impulse voltage: 20 kV
Rated isolation voltage
Protection against
electric shock by
Overvoltage category OV3,
pollution degree PD3
WWW.OCTSOURCES.COM
Summary of Contents for P51000K11-M1M/11