PLACING THE AIR COMPRESSOR
The air compressor should always be placed in clean, dry and well-ventilated area. It should
be located at least 30cm awaydm walls or any other obstruction that could interfere with the
flow of air. The pump and the shroud of the compressor are designed to allow proper cooling.
The ventilation openings on the compressor are necessary to maintain a proper operating
temperature. Do not place rags or other containers on or near these openings.
POWER SOURCE
The motor is designed for operation only on the voltage and frequency specified. Normal loads
can be handled safely on voltages not more than 10% above or below the specified voltage.
Operating compressor on voltages that are not within the range. may cause overheating and
motor burnout. Heavy loads require that the voltage at the motor terminals be no less than
the voltage specified on the nameplate.
This air compressor requires a 230-volt, 50 Hz power source.
GROUNDING INSTRUCTIONS
Do not modify the plug that has been provided, if it does not fit the available outlet, the
correct outlet should be installed by a qualified electrician. The plug must be plugged into
an outlet that is properly installed and grounded in accordance with all local codes. If these
grounding instructions are not completely understood or if there is any doubt as to whether
the compressor is properly grounded, have the installation checked by a qualified electrician.
230V
Grounded
outlet box
Grounded
outlet
Grounding
Plug
This product is for use on a nominal 230 volt circuit. A cord with a grounding plug as shown
here shall be used. Make sure that the product is connected to an outlet that matches the plug.
No adapter should be used with this product.
(AREAS WITH DIFFERENT CIRCUITS PLEASE