20
AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE
EN - Rev. 1.6
-
IT IS MANDATORY TO HAVE AN INITIAL VERTICAL SECTION OF AT LEAST 1.5 MT IN ORDER TO GUARANTEE
CORRECT FLUE GAS DISCHARGE.
-
Every direction change must be carried out with a T-shaped fitting and inspection cap. The tubes must be air tight
through special seals which resist up to 250° C. Attach the pipes to the wall with special collars to avoid any vibration.
-
IT IS STRICTLY FORBIDDEN TO INSTALL DRAUGHT REGULATION VALVES (BUTTERFLY VALVES).
If the flue should be old or too big (internal diameter greater than 15 cm), duct the flue using a stainless steel pipe,
properly insulated with rock wool or vermiculite, and sized according to the route. The connection to the flue must be
appropriately sealed.
When assembling the flue, there must be no more than 4 direction changes, including the initial T-shaped
fitting.
Chimney
The chimney is a device crowning the flue, used to ease dispersion of combustion products.
It must satisfy the following requirements:
-
It must have a usable outlet cross-section no less than double that of the flue onto which it is inserted;
-
In must be shaped in such a way as to prevent rainwater or snow from seeping into the flue;
-
It must be built in such a way as to ensure the discharge of combustion by-products even in the event of winds from
every direction and inclination.
Summary of Contents for AURA 120
Page 2: ......
Page 11: ...6 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 Overall dimensions AURA 80...
Page 14: ...9 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 Overall dimensions REA 100...
Page 62: ...57 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 WIRING DIAGRAM...
Page 65: ...60 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6...
Page 66: ...61 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6...
Page 67: ...62 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6...