AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE
EN - Rev. 1.6
The table below shows the settings and their meanings:
Menu
Meaning
Values that can be set *
CARD BEEP
Enables/disables the beep sound made by the power card
ON – OFF
DISPLAY ILLUMINATION
Regulates the duration of the display illumination
2 / 10 secs
DISPLAY ON
Regulates the duration of the display activation
15 / 60 secs – ON
DISPLAY BRIGHTNESS
Enables/disables display illumination
ON – OFF
DISPLAY CONTRAST
Regulates the display contrast
15 / 60 #
KEY BEEP
Enables/disables the beep sound made each time a key on the remote control is
pressed
ON – OFF
* The values set affect the life of the batteries fitted in the remote control.
Menu 06 – Initial load
Enables pellet pre-loading for 90” when the appliance is switched off and cooled down. Start the function with key 1
(Increase) and stop with key 3 (On/Off). This may be useful if the appliance is switched on after the tank has been
completely emptied, or when it is filled for the first time. Warning: once the operation has been completed, before
switching on the appliance you should remove any accumulation of pellets deposited inside the ash drawer.
Menu 07 – Fireplace status
Allows for viewing the current status of the appliance, by showing the operating conditions of the various devices
connected to it. Several pages are displayed in succession. The data is reserved for Technical assistance Centre.
The table below shows the various devices and their meanings:
Display
Meaning
L04-270218 (example)
Firmware code loaded in the control unit.
ARIA 1.0 (example)
Firmware code loaded in the remote control.
F.GS.T
Indicates the temperature read by the sensor inside the combustion chamber.
R.TMP.
Indicates the room temperature as measured by the sensor inside the remote control.
R.TMP 1
If a temperature sensor is connected, this indicates the temperature in ducted room 1 measured by the same.
If a room thermostat is connected, this indicates the status of the same
(OFF = R.T. contact OPEN = Thermostat not in demand)
(ON = R.T. contact CLOSED = Thermostat in demand)
R.TMP 2
If a temperature sensor is connected, this indicates the temperature in ducted room 2 measured by the same.
If a room thermostat is connected, this indicates the status of the same
(OFF = R.T. contact OPEN = Thermostat not in demand)
(ON = R.T. contact CLOSED = Thermostat in demand)
EX.RPM
Indicates the speed of the flue extractor fan.
LOAD
Indicates the pellet loading interval.
R.T. STATUS
Indicates the status of the main room thermostat.
(OFF = R.T. contact OPEN = Thermostat not in demand)
(ON = R.T. contact CLOSED = Thermostat in demand)
SPE.AIR
Indicates the speed of the front air fan.
SPE.DUC1
Indicates the speed of ducted air fan 1.
SPE.DUC2
Indicates the speed of ducted air fan 2.
TIMER 1
Indicates the end (minutes) of the current operating phase.
TIMER 2
Indicates the end (seconds) of the current operating phase.
DEL.ALARM
Indicates in an alarm state, the time (seconds) before the alarm condition is shown on the display.
T.CARD.
Indicates the temperature read by the sensor inside the control unit.
Summary of Contents for AURA 120
Page 2: ......
Page 11: ...6 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 Overall dimensions AURA 80...
Page 14: ...9 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 Overall dimensions REA 100...
Page 62: ...57 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 WIRING DIAGRAM...
Page 65: ...60 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6...
Page 66: ...61 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6...
Page 67: ...62 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6...