38
AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE
EN - Rev. 1.6
Modify ducted air speed Set values
-
To modify the speed of the ducted air fans (1 or 2 according to the model), select
“SET DUCTING”
by pressing key 5
(Esc).
-
Press key 2 (Decrease) to modify the value for the ducted air fan for zone 1 and confirm by pressing key 4 (Set) or 5
(Esc); the value can be set manually from 1 to 5, or set to automatic (A) connected with the value set in
“SET POWER”
(see
“Modifying the power Setting”)
.
-
Press key 1 (Increase) to modify the value for the ducted air fan for zone 2 and confirm by pressing key 4 (Set) or 5
(Esc); the value can be set manually from 1 to 5, or set to automatic (A) connected with the value set in
“SET POWER”
(see
“Modifying the power Setting”)
.
-
Pressing key 3 (On/Off) or waiting a few seconds without confirming will mean that the set value is not saved.
During this operation, the display will appear as in the following picture:
Modifying the temperature Setting for ducted rooms
See the chapter on
“THE MENU
” under the section “Menu 12 – Set Room. Duc.”.
SET DUCTING 1
(Speed of ducted air fan for
zone 1)
SET DUCTING 2
(Speed of ducted air fan for
zone 2)
POWER SET
(Working power values
between 1 and 5 can be
set.)
Summary of Contents for AURA 120
Page 2: ......
Page 11: ...6 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 Overall dimensions AURA 80...
Page 14: ...9 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 Overall dimensions REA 100...
Page 62: ...57 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 WIRING DIAGRAM...
Page 65: ...60 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6...
Page 66: ...61 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6...
Page 67: ...62 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6...