22
AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE
EN - Rev. 1.6
Connection to the room thermostat or a room temperature sensor
On the back of the appliance there are one or more terminal boards which are used to connect the room thermostat or
room temperature sensor (see “Components of the appliance”)
The table below describes the functions of the terminals on the rear panel of the appliance.
Terminal
Description
Type of control
Action
1
Main room
Only with room Thermostat
*
With the contact CLOSED the appliance will continue to operate at the set
power, independently of the SET ROOM (key 1) setting and the status of any
other connected thermostats or temperature sensors.
With the contact OPEN the appliance will switch to modulation mode as long
as the room temperature set in the SET ROOM (key 1) setting is satisfied and
any other connected thermostats or temperature sensors are satisfied.
2
Ducted room 1
(present only on
models with one or
two ducted outlets)
With room Thermostat *
(Pr56 must be enabled with
value T1 or T1+2)
With the contact CLOSED the appliance will continue to operate at the set
power, independently of the SET ROOM (key 1) setting and the status of any
other connected thermostats.
With the contact OPEN the appliance will switch to modulation mode as long
as the room temperature set in the SET ROOM (key 1) setting is satisfied and
any other connected thermostats are satisfied.
Ducted fan 1 will switch to modulation mode in any case.
With Room sensor **
(Pr56 must be enabled with
value S1 or S1+2)
Once the SET ROOM 1 temperature setting is reached (Menu 12-SET AMB.
CAN.), the appliance will switch to modulation mode as long as the room
temperature set in the SET ROOM (key 1) setting is satisfied and any other
connected thermostats or temperature sensors are satisfied.
Ducted fan 1 will switch to modulation mode in any case.
3
Ducted room 2
(present only on
models with two
ducted outlets)
With room Thermostat *
(Pr56 must be enabled with
value T2 or T1+2)
With the contact CLOSED the appliance will continue to operate at the set
power, independently of the SET ROOM (key 1) setting and the status of any
other connected thermostats.
With the contact OPEN the appliance will switch to modulation mode as long
as the room temperature set in the SET ROOM (key 1) setting is satisfied and
any other connected thermostats are satisfied.
Ducted fan 2 will switch to modulation mode in any case.
With Room sensor **
(Pr56 must be enabled with
value S2 or S1+2)
Once the SET ROOM 2 temperature setting is reached (Menu 12-SET ROOM.
CAN.), the appliance will switch to modulation mode as long as the room
temperature set in the SET ROOM (key 1) setting is satisfied and any other
connected thermostats or temperature sensors are satisfied.
Ducted fan 2 will switch to modulation mode in any case.
* Connect a room thermostat with no power to manage a simple clean contact, preferably with a hysteresis value that
can be calibrated.
** Connect a type "NTC 10K ± 1%” room sensor.
Summary of Contents for AURA 120
Page 2: ......
Page 11: ...6 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 Overall dimensions AURA 80...
Page 14: ...9 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 Overall dimensions REA 100...
Page 62: ...57 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 WIRING DIAGRAM...
Page 65: ...60 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6...
Page 66: ...61 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6...
Page 67: ...62 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6...