9.3 Settings
Access to these settings is password-protected (default: 1111).
Table no. 17
Settings menu
Group
Name
Default
value
Description / Settings menu
Temper
atur
es
Master sensor
Air
supply
Air supply
– temperature adjustment according to air supply temperature sensor
Air exhaust
– temperature adjustment according to air exhaust temperature sensor
HMI CON
– temperature adjustment according to temperature sensor in the HMI programming device connected to the HMI CON connector
HMI RS485
– temperature adjustment according to temperature sensor in the HMI programming device connected to the RS485 connector
PT5
– temperature adjustment according to temperature sensor connected to the PT5 sensor input (do not use it if PT5 is used as a return
water sensor)
Auto
– temperature adjustment according to temperature sensor of the air supply section (in winter) and air exhaust section (in summer)
Eco temperature
difference
15°C
This function is used both for heating and cooling; it prevents from heating/cooling when external temperature is higher/lower by set value
than air exhaust temperature sensor (this function is active only in air supply-exhaust systems)
Start ramp
600 s
Start ramp
– drop time of increased requested temperature in systems with water heater and delay of switching on the cascading tem-
perature controller
Correction
of requested
temperature
5°C
Correction of set temperature
– set point of set value increase and air supply min temperature at the system start
Season
Operation mode
Auto
Important option for the master sensor in Auto mode.
Auto
– year season determined automatically based on the external temperature sensor
Winter
– manual set point of winter operation mode
Summer
– manual set point of summer operation mode
Temperature –
summer
20°C
Temperature – summer
– external temperature threshold setting above which the system operates in the summer mode, the leading
sensor (set in auto mode) is the air exhaust sensor and the HPM module can operate in cooling mode
Hysteresis
4°C
Hysteresis
– the hysteresis setting for the „Summer.temp” threshold, the external temperature drop below the difference between the
„Summer.temp” and „Hysteresis” makes the system operate in winter mode, the leading sensor (set in auto mode) is the air supply sensor
and the HPM/CM module can operate in heating mode.
Standb
y mode
Temperature
setting
22°C
Temperature setting
– set temperature settting of the standby mode master sensor, (however temperature adjustment is carried out according to the
master temperature sensor and temperature set point from the main menu)
Standby master
sensor
HMI CON
Air exhaust
– switching on the system according to the air exhaust temperature sensor
HMI CON
– switching on the system according to the air exhaust temperature sensor in the HMI programming device connected via HMI CON
HMI RS485
– switching on the system according to the air exhaust temperature sensor
PT5
– switching on the system according to temperature sensor connected to the PT5 sensor input (do not use it if PT5 is used as a return water sensor)
Active for
Heating
and
cooling
Heating
– system is started, when the standby mode master sensor temperature drops below the set standby temperature by the standby
hysteresis value
Cooling
– system is started, when the standby mode master sensor temperature exceeds the set standby temperature by the standby
hysteresis value
Heating and cooling
– system is started, when the standby mode master sensor temperature drops below or exceeds the set standby
temperature by the standby hysteresis value
Standby hysteresis
4°C
A difference between the standby temperature sensor and the set standby temperature above which the system is activated while operating
in the standby mode
Summary of Contents for EVO -T
Page 2: ...SERWIS SERVICE 48 587839950 51 48 587839888 48 510098081 serwis klimor com...
Page 39: ...37...
Page 41: ...39...
Page 55: ...53 NOTATKI...
Page 56: ...SERWIS SERVICE 48 587839950 51 48 510098081 serwis klimor com...
Page 91: ...89 CONTROL AUTOMATION CONTROL...
Page 107: ...105 NOTES...
Page 108: ...SERWIS SERVICE 48 587839950 51 48 510098081 serwis klimor com...
Page 109: ...A Y EVO T EVO T COMPACT KLIMOR EVO T_CS...
Page 115: ...113 5 7 1 2 1 2 DX 1 2 13 C 1 2 1 C 1 2 30...
Page 145: ...143 26 2S 27 2S...
Page 146: ...144 EVO T EVO T COMPACT 28 EH M 18kW 1 PE_ PE_ Max 18...
Page 147: ...145...
Page 148: ...146 EVO T EVO T COMPACT 29 EH M 36 kW 3 Max 12 Max 12 Max 12 PE_ 0 5mm2 blue 0 5mm2 white...
Page 149: ...147 0 5mm2 0 5mm2 0 5mm2 0 5mm2 0 5mm2 0 5mm2 0 5mm2...
Page 150: ...148 EVO T EVO T COMPACT 30 4S 31 4S...
Page 155: ...153 1 2 3 40 15 1 8 HMI HMI OK C HMI 15 1 9 HMI 3 C Alarms history 41 42...
Page 161: ...159 16...
Page 162: ...160 EVO T EVO T COMPACT...
Page 163: ......