4-10
CHAPTER 4 Equipment Maintenance
HydroChart 5000 Sonar Operations and Maintenance Manual
P/N 11210080, Rev. 02
16.
Lay the sonar electronics
housing on a dry, flat
surface, and then grasp the
threaded rod and carefully
pull the chassis completely
out of the housing. Be
careful not to scratch the
O-ring surface inside the
housing.
4.3.2 Reassembling
the Sonar Head
Unit
To reassemble the Sonar Head
Unit:
1.
If the sonar electronics
chassis was removed, verify
that the O-ring on the
connector end cap is clean
and free of dirt or scratches.
If the chassis was not
removed, proceed to Step 5.
If dirt or scratches are
present, replace the O-ring.
When replacing the O-ring,
first clean the O-ring
surface inside the housing and the O-ring groove in the end cap using a lint-
free cloth or paper towel, and then apply a
light
coat of silicone grease to the
O-ring before installing it.
2.
Insert the chassis into the housing and align the locator pin in the end cap with the
slot in the housing.
3.
Push the connector end cap into the housing until it is fully seated.
Figure 4-14:
Pulling the Sonar Electronics
Chassis out of the Sonar Electronics Housing
Figure 4-15:
Aligning and Installing the
Connector End Cap