Disassembling and Reassembling the Sonar Head Unit
4-9
To continue with the removal
of the sonar electronics
chassis:
14.
Using the 4-mm hex key,
tighten
the two socket head
cap screws in the
electronics housing
connector end cap.
15.
Insert the 7-inch, 1/2 x 13
threaded rod into the
threaded hole in the middle
of the connector end cap
and hand tighten.
Figure 4-12:
Tightening the Socket Head Cap
Screws in the Electronics Housing Connector
End Cap
Socket head
Connector
end cap
cap screw (2)
Figure 4-13:
Inserting the 7-inch, 1/2 x 13
threaded rod into the Connector End cap
7-inch, 1/2 x 13
threaded rod
Summary of Contents for HydroChart 5000