To connect the TPU and the SonarPro Workstation:
1.
Connect the Ethernet cable to the LAN connector on the TPU and to either
one of the two the ETHERNET connectors on the SonarPro Workstation.
2.
Connect the monitor to the DVI connector on the SonarPro Workstation and
connect the monitor power supply to the AC power source.
3.
Connect the keyboard and the mouse to any two of the six USB connectors on
the SonarPro Workstation.
4.
Connect a GPS to the NAV connector on the TPU. A user supplied RS-232
serial cable is required where one end is terminated with a DB9 female
connector and the other end is as required by the navigation system.
5.
Verify that the GPS is outputting NMEA-0183 formatted data strings at
4800 baud, no parity, 8 data bits, and 1 stop bit. In addition, the GPS should be
outputting the following messages:
• GLL or GGA
• VTG
• RMC (optional)
6.
Connect the deck cable to the TOWFISH connector on the TPU.
7.
Connect an AC power cable to the AC INPUT connectors on the TPU and the
SonarPro Workstation and to the AC power source.
The following connections are optional:
8.
Connect the 1 PPS connector on the TPU to the 1 PPS output of the shipboard
GPS. A user supplied BNC-to-BNC cable is required.
9.
Connect the T/F TRIG connector on the TPU to the trigger input of an
external sonar system. A user supplied BNC-to-BNC cable is required.
10.
Connect the TRIG A connector on the TPU to the trigger input of a USBL
system. A user supplied BNC-to-BNC cable is required.
11.
Connect the COM B (Sound Velocity) connector to the sound velocity sensor
if installed on the Sonar Head Unit.
12.
Connect the COM C (Motion Reference Unit) connector to the motion
reference unit if available.
NOTE
If 4800 baud is not available from the GPS, contact KMS customer
service for instructions on how to reconfigure the system to accept a
different baud rate. Refer to “Customer Service” on page xvii for