3-8
CHAPTER 3 Preparation for Deployment
HydroChart 5000 Sonar Operations and Maintenance Manual
P/N 11210080, Rev. 02
TRIG A:
BNC connector that connects to an ultra short
baseline navigation system (USBL). Provides a TTL
compatible, 100-µs wide output pulse with each
trigger of the optional responder.
1 PPS:
BNC connector that connects a GPS and is used to
input 1 PPS (one pulse per second) signals.
TOWFISH:
Type N coaxial connector that connects to the Sonar
Head Unit.
AC INPUT:
IEC type connector that connects to the AC power
source.
3.6.2 SonarPro Workstation Connections
All the connections to the SonarPro Workstation are made to connectors on the
back panel which is shown in Figure 3-5.
The SonarPro Workstation connectors are the following:
USB:
USB connectors (4, plus 2 on the front panel). Any
two connect to the keyboard and the mouse. The
front panel USB connectors are shown in Figure 3-7
on page 3-14.
DVI:
DVI connector that connects to the monitor.
ETHERNET:
RJ-45 connectors (2). Any one connects to the LAN
connector on the TPU.
AC INPUT:
IEC type AC input connector that connects to the
AC power source.
3.7
Connecting the Topside System Components
The following cables are required to connect the TPU and the SonarPro
Workstation:
• Ethernet cable
• AC power cords (2)
• Deck cable
WARNING
Before connecting the topside system components, verify that
the TPU is turned off and that its power cord is disconnected. Failure to
follow this practice may result in personal injury or damage to the Sonar
Head Unit or to the TPU electronics, or to both. For the location of the power
switches, refer to “Topside System Controls and Indicators” on page 3-11.