5
-
dk4210(c)HSE / dk4710(c)HSE / dk5310(c)HSE / dk6010(c)HSE
Port
Coupler Size
A, B, c, d
pT 1 / 2
lever 1
Push
Pull
valve
1 port
A out
In
B In
out
lever 2
Push
Pull
valve
2 port
c out
In
d In
out
pressure
Returning
This machine is equipped with one
double-acting valves (detent type)
which can supply hydraulic pressure
to exterior devices. Utilize them prop-
erly according to implement specifi-
cations.
• For the self-return type double act-
ing lever, it returns to its neutral
position to block the hydraulic fluid
when it is pushed/pulled and then
released. Therefore, this type of
double acting valve lever should be
pulled or pushed continuously for
operation which is suitable for an
implement with a short operating
time, such as a hydraulic cylinder.
• For the detent type double acting
valve lever, it keeps its position af-
ter it is pulled or pushed to a certain
position. Therefore, it is not neces-
sary to hold the lever to a certain
position which is suitable for an
implement with a long operating
time, such as the hydraulic motor.
Additionally, you can attach one
more double acting valve please
contact
KIOTI
dealer.
Td2O524a
(1) double Acting valve 1, lever 1
(2) double Acting valve 2, lever 2
(A) port A
(c) port c
(B) port B
(d) port d
REmOTE HYDRAUlICS
DOUblE ACTING lEvER (If EqUIPPED)
TD210-미국법인향-DK4210,4710,5310,60122 22
2019-09-26 오전 9:43:52
Summary of Contents for DK4210(C)HSE
Page 42: ...MEMO memo TD210 DK4210 4710 5310 6016 6 2019 09 18 4 09 19...
Page 152: ...MEMO MEMO TD210 DK4210 4710 5310 60118 18 2018 03 30 6 41 40...
Page 196: ...MEMO memo TD210 DK4210 4710 5310 60144 44 2019 09 18 4 53 51...
Page 207: ...10 10 INDEX INDEX 10 2 TD210 DK4210 4710 5310 6011 1 2019 10 11 10 59 37...
Page 214: ...7 TD210 DK4210 4710 5310 6018 8 2019 10 11 10 59 38...