4
4
-
1
Function description and operating tips
td2o435e
Flashed
warning
in the warning level 3 (cel lamp
on), both manual and auto-
matic regeneration processes
cannot be performed.
when the dpF warning lamp
comes on, make sure to perform
the manual regeneration as the
active regeneration cannot be per-
formed.
enabling condition for manual
regeneration
- brake on
- engine rpm idle state
if any of the above conditions is
not met during regeneration, the
regeneration mode is deactivated.
•
•
•
•
td2o436c
2.
stage 2 warning lamp for dpF
clogging
: dpF soot loading level 160% -
200%
Manual regeneration required.
engine rpM limit is activated
(below 2,200 rpm)
if the dpF is not regenerated in the
stage 1 warning state, the warning
lamp blinks. in this state, make sure
to perform dpF regeneration pro-
cess. (see page 4-11)
3. stage 3 warning lamp for dpF
clogging
: dpF soot loading level 200%
or higher
passive regeneration prohibited.
engine rpM limit is activated
(below 2,200 rpm)
if the dpF is still not regenerated
even in stage 2, the check engine
lamp comes on and the dpF needs
to be replaced.
TD210-미국법인향-DK4210,4710,5310,60119 19
2020-11-18 오후 2:34:53
Summary of Contents for DK4210(C)HSE
Page 42: ...MEMO memo TD210 DK4210 4710 5310 6016 6 2019 09 18 4 09 19...
Page 152: ...MEMO MEMO TD210 DK4210 4710 5310 60118 18 2018 03 30 6 41 40...
Page 196: ...MEMO memo TD210 DK4210 4710 5310 60144 44 2019 09 18 4 53 51...
Page 207: ...10 10 INDEX INDEX 10 2 TD210 DK4210 4710 5310 6011 1 2019 10 11 10 59 37...
Page 214: ...7 TD210 DK4210 4710 5310 6018 8 2019 10 11 10 59 38...