SUPPORT STRAPS
EVERY 2 FEET
20 FEET
FIGURE 2
7 FEET
35.0"
SIDE VIEW
Important Minimum clearances of
flue pipe to combustibles.
Vertical runs 1.0".
Top horizontal run with sleeve
requires 2.0" clearance
in low profile enclosure.
2.5" rise per ft. for
horizontal runs with
min. vertical from
Fireplace.
For installations other than Low Profile
Enclosures, top of horizontal with no
sleeve requires a 2.5" clearance, and
4.0" of clearance above 90° elbow.
SUPPORT STRAPS
EVERY 2 FEET
SUPPORT STRAP
ON 90° BEND
Requires 1/4" Rise
per foot.
Based on 90°
installations
20 FEET
FIGURE 3
FIGURE 4
7 FEET
6 Ft.
T
O
T
AL VER
TICAL
SIDE VIEW
SIDE VIEW