FRAMING
Using 2x4s frame to local building codes.
DO NOT install against a Vapour Barrier or Exposed
Insulation.
Framing measurements have been adjusted to
accommodate a 1/2" thick finished wall. FIGURE 1
Combustible materials may be installed flush with
the top and sides of fireplace.
It is not necessary to install a hearth with this
fireplace system. Objects placed in front of the
fireplace should be kept a minimum of 24" away from
the front face.
Fireplace bottom supplies you with two 6"x8"
holes. The use of these holes depends on valve
and Fireplace location on riser or upper floor.
FIREPLACE ASSEMBLY
1. Mount Door Cover Figure #2. First apply a
small bead of High Heat Silicone to door seal.
Mount Door and screw into place, making sure that
Door is properly sealed.
2. Hang Heat Shield on top edge of fireplace,
and secure with self tapping screws. Heat
Shield must be centered allowing a 1/2"
clearance both sides of Fireplace for
finishing material.
3. The heat shield and rear
standoff are equipped with
nailing tabs. Level Fireplace and
nail or screw into place.
NOTE.
For Low Profile Enclosure Refer
to
Low Profile Enclosure Section
.
R/H FIREPLACE SHOWN
FRAMING DETAIL
THROUGH Combustible WALL
11.0"
11.0"
MIN.
6.5"
MIN.
39.0"
MIN.
36.0"
SIDE FLUE
APPLICATION
REAR FLUE
APPLICATION
3.5" TYP.
L/H Framing
Instructions
R/H Framing
Instructions
GAS LINE
R/H UNIT
BOTTOM
ENTRY
2.0" x 3.0"
Notch for
End gas
line entry
37.0"
37.0"
14.5"
6.0"
8.0"
2.5"
7.0"
23.75"
38.125"
4.188"
27.25"
27.25"
38.125"
25.875"
23.75"
42.0"
For Combustible
Enclosure Top.
FIGURE 1
FIGURE 2
REAR STAND OFF
COMPLETE WITH
NAILING TABS
HEAT
SHIELD
COMPLETE
WITH
NAILING
TABS
DOOR
COVER
HIGH HEAT
SILICONE
NAILING TABS
NOTE:
Clearance to back of unit and/or sides of unit
framed into walls require 6” minimum clearance to com-
bustibles. We recommend using two (2 x 4) studs placed
against the wall as per framing diagrams. See
Locating your Appliance for additional information.
Framing Corner L/H & R/H Installation Instructions - Louvered Unit Only
NOTE: The standoffs are non load bearing.
When installing a cabinet, a maximum weight
of 250 lbs can be installed on the 1/2” drywall
lip (located around the perimeter of the appli-
ance).
7
Summary of Contents for MDV31
Page 41: ...Gas Conversion for Modulator PART C WARNING WARNING 41...
Page 44: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 44...
Page 45: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 45...
Page 46: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 46...
Page 54: ...For Models MDV31 39 Replacement Parts continued 54...