FRAMING
Using 2x4s frame to local building codes.
DO NOT install against a Vapour Barrier or Exposed
Insulation.
Framing measurements have been adjusted to
accommodate a 1/2" thick finished wall. FIGURE 1
Combustible materials may be installed flush with top
and sides of fireplace.
It is not necessary to install a hearth with this
fireplace system. Objects placed in front of the fireplace
should be kept a minimum of 24" away from the front face.
Gas line installation should be performed only after
Fireplace installation. Fireplace bottom supplies you with
two 6"x8" rectangular holes. The use of these holes
depends on valve and Fireplace location on riser or upper
floor.
NOTE
Low profile enclosure 42.0" to 52.0"
must maintain a minimum clearance of
2" from top of 7.0" flex pipe and
insulation sleeve to bottom of combustible
enclosure top. Insulation sleeve
must be installed so that it covers 7.0"
flex pipe from fireplace up and to wall
sleeve.
Refer to
Low Profile Enclosure Section
for additional
information.
FRAMING DETAIL
HORIZONTAL RUN
WITH MIN. VERTICAL RUN
MIN.
36.0"
FIGURE 1
THROUGH
COMBUSTIBLE
WALL
11.0"
11.0"
42.0" MIN.
For Combustible
Enclosure Top
INSULATION
SLEEVE
NAILING TABS
REAR STAND OFFS
COMPLETE WITH
NAILING TABS
2.5"
6.0"
11.062"
38.125"
37.0"
20.625"
GAS LINE
R/H UNIT
BOTTOM
ENTRY
2.0" X 3.0"
NOTCH FOR
END GAS
LINE ENTRY
GAS LINE
L/H UNIT
FIGURE 2
FIREPLACE ASSEMBLY
Rear standoffs are equipped with
nailing tabs. Level Fireplace nail or screw
into place.
NOTE!
For Log, Crushed Rock and Glowing Ember
installation refer to
Log Placement Section
.
NOTE:
Clearance to back of unit and/or sides of unit
framed into walls require 6” minimum clearance to com-
bustibles. We recommend using two (2 x 4) studs placed
against the wall as per framing diagrams. See
Locating your Appliance, for additional information.
Framing Peninsula Installation Instructions - Louvered Unit Only
NOTE: The standoffs are non load
bearing. When installing a cabinet, a
maximum weight of 250 lbs can be
installed on the 1/2” drywall lip (located
around the perimeter of the appliance).
16
Summary of Contents for MDV31
Page 41: ...Gas Conversion for Modulator PART C WARNING WARNING 41...
Page 44: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 44...
Page 45: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 45...
Page 46: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 46...
Page 54: ...For Models MDV31 39 Replacement Parts continued 54...