Fig 8 Normal Mode 1 of PV and AC
2.
When the PV power is less than the load power, the PV together with the AC will supply
the power to the load and battery
Fig 9 Normal Mode 2 of PV and AC
4.2
When AC abnormal or AC absent
1.
When PV power is greater than the load power and AC fails, the PV power will support
the load at first and the extra power will be used to charge the battery.
Fig 10 AC Abnormal Mode 1
2.
When the PV power is less than the load power and AC fails, the PV together with the
battery will supply the power to the load. When the battery discharges then the system
automatically shuts down and the PV will charge the battery. When the battery is fully
recharged or AC runs normally, the system automatically will be ON.
Fig 11 AC Abnormal Mode 2