43 of 56
Revision 4
KiloVault
®
LLC • 330 Codman Hill Road, Boxborough, MA 01719 • +1 (888) 218-5924 •
• www.kilovault.com
5.6.
Maintenance
There are no user serviceable parts inside of the KiloVault® HAB™ V4. Do not
open the KiloVault® HAB™ V4 case. Simply keep the exterior clean, dry, and
dust free.
5.7.
Disposal
Please contact your local solid waste recycling agency for recycling instructions.
Do not dispose of this equipment with household waste.
6.
Troubleshooting
6.1.
BMS Protection / Alarm Conditions
Alarm events cause the ALARM LED on the front panel to flash. Protection
events cause the ALARM LED to flash and will cause the KiloVault® HAB™ V4 to
shut down for the indicated time period.
Alarm / Protection Condition
Trigger Values
High Voltage Alarm for each Cell
3.55±0.03 V
High Voltage protection for each cell
3.75±0.03 V, Delay time: 1s
High Voltage release for each cell
3.40±0.03 V
High Voltage alarm for total voltage
56.8 V±0.5 V
High Voltage protection for total voltage
60.0 V±0.5 V, Delay time: 1s
High Voltage release for total voltage
54.4 V±0.5 V