RC04-PCR-LA
Operation Method 4-35
For the F5 (Arms) key, the each harmonic component is indicated
as a current value. The unit is Arms.
5. Press the MENU key to switch the display and change the
displayed harmonic order.
If “ALL” is selected in step 3, ten displays (up to the 40th order)
are available. For “ODD” or “EVEN”,
fi
ve displays are provided.
The display changes whenever the MENU key is pressed.
To return to the previous display, press the (SHIFT, MENU) keys.
6. Press the ESC key to return to the Home Position.
This will cancel the key-lock mode in the PCR-LA power supply.
Pressing the ESC key on the PCR-LA power supply also returns
the status to the Home Position.
• Harmonic analysis can be performed using the PCR-LA
Series only. However, harmonic analysis generally requires
that line impedance is adjusted to the standard value. There-
fore, the Line Impedance Network (LIN Series) is also neces-
sary.