158
PBZ
A
List of Factory Default Settings
Resetting the PBZ to its default values
If you hold down the SHIFT key while you turn the POWER switch on, the PBZ starts up with
the factory default settings. Continue holding down the SHIFT key until the initial screen is
displayed.
Operation mode and signal sources
Item
Factory default
setting
Operation
mode
CONTROL
CV/CC mode
CV
POLARITY
Bipolar/unipolar mode
BIPOLAR
Signal source
selection
SELECT
Internal, external, and addition
INT
EXT SELECT
External signal source
BNC
External
signal input
(BNC
terminal)
EXT GAIN
Gain
0.0 (not inverted)
DC signal
DC
DC
CV: 0.000 V
CC: 0.000 A
FINE
Fine adjustment of the DC setting
CV: 0.0000 V and
CC: 0.0000 A
SOFT START
SOFT STOP
Soft start time
Soft stop time
OFF
AC signal
FUNC
Waveform
SIN (sine wave)
AMPL
Amplitude
CV: 0.0 Vp-p
CC: 0.0 Ap-p
FREQ
Frequency
1000.00 Hz
PHASE
Start phase
0 deg
DUTY
Square wave duty cycle
50.0 %
AC
AC signal: on/off
OFF
SWEEP
Frequency sweep: on/off
OFF
MODE
Sweep mode
LINEAR
TIME
Sweep time
1.0000 s
START
Sweep start frequency
100.00 Hz
STOP
Sweep stop frequency
1000.00 Hz
TRIG OUT
TRIG OUT terminal: on/off
OFF
MARKER FREQ
Marker frequency
500.00 Hz
Response
VOLT
CV mode
3.5 µs
CURR
CC mode (PBZ20-20)
35 µs
CC mode (PBZ40-10)
70 µs
Remote
sensing
SENSING
OFF
Summary of Contents for PBZ20-20
Page 11: ...PBZ 11 ...
Page 18: ...18 PBZ ...
Page 95: ...Sequences This chapter explains sequences ...
Page 153: ...Maintenance This chapter describes how to clean and inspect the PBZ ...
Page 156: ...156 PBZ Maintenance ...