KDS6-0.2TR
Remote Control 37
VSET
Sets the voltage values of Channels 1 to 3 collectively or inquires about the present
settings collectively.
Program message
•
Syntax
Command message:
VSET <CH1 setting value>, <CH2 setting
value>, <CH3 setting value>
Setting values are delimited with “,” (ASCII:2Ch).
Query message:
VSET?
•
Program data
(Example) To set Channel 1 to 2.8001 V, Channel 2 to 1 V, and Channel 3 to 0.5 V:
VSET 2.8001,1,0.5
Response message
In response to
VSET?
, the present settings of the channels are delimited with
“,” (ASCII:2Ch) and returned as fixed decimal point data (0.0000 to 6.5000).
The data is returned in the order of CH1, CH2, and CH3.
(Example)
2.80001,1.0000,0.5000
Setting of voltage value for Channels 1 to 3
Minimum value
0.0000
Maximum value
6.5000
Resolution
0.0001
Data format
Fixed decimal point
Initial value
0.0000
Unit
V
Summary of Contents for KDS6-0.2TR
Page 1: ...OPERATION MANUAL Precision DC Source Part No Z1 003 132 I0040701 May 2021 KDS6 0 2TR ...
Page 4: ...ii KDS6 0 2TR ...
Page 8: ...4 Safety Precautions KDS6 0 2TR ...
Page 12: ...8 Introduction KDS6 0 2TR ...
Page 22: ...18 Names and Functions of Parts KDS6 0 2TR ...
Page 30: ...26 Basic Operations and Connections KDS6 0 2TR ...
Page 52: ...48 Maintenance and Calibration KDS6 0 2TR ...
Page 58: ...54 Index KDS6 0 2TR ...
Page 59: ......