Assembly Instructions
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
17
Installing Vertical Jumper
WARNING:
Assembly of all
mechanical frame components
must be completed before
making any electrical
connections. All electrically
connected furnishings must also
be mechanically connected.
Verticals jumpers are used to
run power within a single panel
between two different heights.
There are two lengths of vertical
jumpers: 20” and 56”. The 56”
long vertical jumper is capable of
running power from the base to
any other height within the panel.
The 20” short vertical jumper
is used to run power between
two adjacent heights (i. e. ADA
height to worksurface height or
worksurface height to standing
height) (Example F).
Note:
The 56” vertical jumper
must be used to run power from
base to ADA height.
1. Install the vertical jumper in the
same manner as the horizontal
jumper, connecting the ends of
the jumper to rigid wireways at
two different heights of the same
panel (Detail E).
Typical rigid wireway and jumper
installation for “810” electrical
system is shown in example F.