TAP Test Plan
3
Keysight X8711A IoT Device Functional Test Solution User’s Guide
32
Test Step and Description
Output
Discover BLE Devices
This step publishes discovered devices to report and initializes BLE radio
to start scanning for BLE devices according to the following settings:
– RSSI Filter (As threshold value)
– Device Discovery Scan Time (Maximum time to scan for devices)
Only display devices with a
higher RSSI value set,
within the specified scan
time.
Measure Advertising Interval
This step must be placed as the child step of
and
will be executed when the BLE device supports Active Scan.
There are four types of advertising interval:
– System Scan Maximum
– System Scan Minimum
– System Scan Average
– User Entry
This step detects the BLE device’s active scan response time based on
these settings:
– BLE Device
– Duration of detection (Range: 1 to 15 seconds)
Set BLE DL Power
This step must be placed as the child step of
and it
will only be executed when a device is selected in this step.
This step initializes the output power for the BLE Signaling PER test
according to the System Offset set.
Range of DL power (dBm): (-100 + System Offset) to (-40 + System Offset)
Note: DL stands for Downlink