TAP Test Plan
3
Keysight X8711A IoT Device Functional Test Solution User’s Guide
33
Active Scan
This step must be placed as the child step of
.
This step acquires BLE signaling PER of an active scan device according to
the following settings:
– Packet Count
– (Upper) PER Limit
– Repeat
Advanced Settings:
– Early Fail count (Maximum consecutive fail packet allowed before
error)
– Scan Delay (Range: 10 milliseconds to 10 seconds)
Any PER values that exceed
the limit, will cause the test
to report ‘Fail’.
– Packet Error Rate
(when repeat = 1)
– Scan Response Bytes
(Total bytes of device’s
scan data)
– Scan data bytes (Content
of device’s scan data)
Connect Request
This step must be placed as the child step of
.
This step acquires BLE Signaling PER of a connect request device based
on the following settings:
– Packet Count
– (Upper) PER Limit
– Repeat
Advanced Settings:
– Early Fail count (Sets the maximum consecutive fail packet allowed
before error)
– Response Iteration (Sets the number of responses to check for each
connected PER test method. Range: 1 to 10)
– PER Method (The connection method for PER test)
– Check Supported PER Methods (Select this check box to discover
which PER methods supported by the DUT)
Any PER values that exceed
the limit, will cause the test
to report ‘Fail’.
– Packet Error Rate
(when repeat = 1)
– Scan Response Bytes
(Total bytes of device’s
scan data)
– Scan data bytes (Content
of device’s scan data)
Test Step and Description
Output