101
6
Performance Plots
N2836A 26 GHz Solder-In Head (with N2803A)
N2838A/N5439A 25 GHz PCB ZIF Tip/Head (with N2803A)
N5440A/N5439A 28 GHz Ceramic ZIF Tip/Head (with N2803A)
N5447A/N5439A 28 GHz Ceramic High-Sensitivity ZIF Tip/Head (with
N5441A 16 GHz Solder-In Head (with N2803A)
N5444A 28 GHz SMA 2.92 mm Head (with N2803A)
N5445A 30 GHz Browser Head, 1 mm span (with N2803A)
N5445A 30 GHz Browser Head, 2 mm span (with N2803A)
N5445A 30 GHz Browser Head, 3 mm span (with N2803A)
The performance plots in this chapter are for the N2803A 30 GHz probe
amplifier with various configurations InfiniiMax III probe heads. Items to
note are:
• When InfiniiMax III probes are used with Keysight Infiniium 90000
X-Series Oscilloscopes (and the Keysight DCA-X Wide-Bandwidth
Sampling Scopes in some cases), probe correction is applied to
enhance the probe accuracy.
• Probe correction is computed from the s parameters of the various
probe components such as probe heads, probe amps, and accessories.
• Typically, the largest variation in a probe’s response is due to variation
in the response of the probe amplifier. For the InfiniiMax III probes, the
s parameters of each probe amplifier are measured at manufacture and
stored in non-volatile memory in the probe amplifier, thus allowing the
removal of this component of variation.
• If care is taken in the manufacture of the probe heads and other
accessories, the variation in the probe response due to these
components is minimal since they tend to be simple passive devices.
Therefore, the s parameters for probe heads and other accessories are
based on an average of a cross-section of parts. These nominal s
parameters are stored in the oscilloscopes firmware based on the
model number of the probe head or accessory and used in conjunction
with the measured probe amplifiers s parameters to compute the
overall probe correction.
Summary of Contents for InfiniiMax III Series
Page 1: ...Keysight InfiniiMax III Series Probes User s Guide...
Page 4: ...4 Contents...
Page 28: ...28 1 Using InfiniiMax III Series Probes Simplified InfiniiMax III Schematic...
Page 64: ...64 2 InfiniiMax III Probe Heads N5444A InfiniiMax III 2 92 mm 3 5 mm SMA Probe Head...
Page 100: ...100 5 Performance Verification Performance Test Record...
Page 104: ...104 6 Performance Plots N2836A 26 GHz Solder In Head with N2803A...
Page 105: ...105 6 Performance Plots N2836A 26 GHz Solder In Head with N2803A...
Page 107: ...107 6 Performance Plots N2838A N5439A 25 GHz PCB ZIF Tip Head with N2803A...
Page 108: ...108 6 Performance Plots N2838A N5439A 25 GHz PCB ZIF Tip Head with N2803A...
Page 110: ...110 6 Performance Plots N5440A N5439A 28 GHz Ceramic ZIF Tip Head with N2803A...
Page 111: ...111 6 Performance Plots N5440A N5439A 28 GHz Ceramic ZIF Tip Head with N2803A...
Page 113: ...113 6 Performance Plots N5447A N5439A 28 GHz Ceramic High Sensitivity ZIF Tip Head with N2803A...
Page 114: ...114 6 Performance Plots N5447A N5439A 28 GHz Ceramic High Sensitivity ZIF Tip Head with N2803A...
Page 116: ...116 6 Performance Plots N5441A 16 GHz Solder In Head with N2803A...
Page 117: ...117 6 Performance Plots N5441A 16 GHz Solder In Head with N2803A...
Page 119: ...119 6 Performance Plots N5444A 28 GHz SMA 2 92 mm Head with N2803A...
Page 121: ...121 6 Performance Plots N5445A 30 GHz Browser Head 1 mm span with N2803A...
Page 122: ...122 6 Performance Plots N5445A 30 GHz Browser Head 1 mm span with N2803A...