User Manual
COGE5, COGE5-F
page 67 of 110
© KEYMILE December 2015
EN/LZTBU 372 144/3 RA
110
Operation and Maintenance
4. Wait until the unit has booted and reconnect as “manager”.
-
The AP: /unit-11 is the only AP available in the AP tree.
-
The AP: /unit-11 is now running in the network element bootloader
(bco5n_rxxxx).
5. Open the MF “Main” and select the tab “Software”.
-
If the desired NE ESW is not available on the unit select the COGE5
NE ESW (co5ne_r2bxx) in the list of “Software On Element Manager”
and click “Download”.
-
Wait until the download is terminated and the ESW appears in the list
“Software On Unit”.
6. In “Configuration” select the downloaded ESW under “Software”.
-
Check that “Software Installation” is set to “Manual Start”.
7. Execute “Apply”.
Please note:
When the COGE5 unit is running in the network element bootloader the
“Save to NE” command is executed automatically when the configuration is
modified.
→ The operator is not allowed to execute a manual “Save to NE” com-
mand.
8. Start the new software.
-
In the MF “Main” of the AP: /unit-11 click the command button “Start
Software”. This reboots the control unit.
9. Wait until the unit has booted, disconnect and reconnect as “manager”.
Result:
The AP: /unit-11 is now running in the unit bootloader
(bco5u_rxxxx).
Result:
The AP: /unit-11/neController is running the NE ESW
(co5ne_r2bxx).
End of instruction
Please note:
To exit from the UN bootloader a UN ESW must be configured and applied
at the AP: /unit-x, Main - Software before restarting the unit.