User Manual
COGE5, COGE5-F
page 102 of 110
© KEYMILE December 2015
EN/LZTBU 372 144/3 RA
110
User Interface Reference
8.9.2
AP: / unit-x / iports / iport-b, Main
8.9.2.1
AP: / unit-x / iports / iport-b, Main – General
For a description of the “Labels” and “Alarm Status” parameters in the
− “Main - General”
management function, please refer to
[302] User Guide “XMC25/XMC23/
8.9.2.2
AP: / unit-x / iports / iport-b, Main – Physical
Table 35:
AP: / unit-x / iports / iport-b, Main – General
Operation Name
Parameter Name Range
Descriptions / Details
Interface Status
Admin Status
Up
Select “Up” to bring the internal port into service
Down
The internal port cannot be set to the Down state.
Oper Status
Up
Shows the operational state is up. The state can only be
up if the administrative state is up and there are cur-
rently no failures.
Down
Shows the operational state is down.
Unknown
The port status is unknown.
Testing
Shows the port is in a testing state.