8.2.5
AP: / unit-x, QoS
8.2.5.1
AP: / unit-x, QoS – Rate Limiting
For a description of the
− “QoS - Rate Limiting”
management function, please refer to
[302] User Guide “XMC25/XMC23/
SWIC
Software Incompatible
With Configuration
Equipment
Alarm
Major
The ESW running on the unit is not com-
patible with the unit configuration stored
in the database. You may need to
upgrade, or downgrade the ESW, or re-
create the configuration with the cur-
rently running ESW.
SWIN
Software Incompatible
With Network Element
Equipment
Alarm
Major
The running ESW is not compatible with
the version required by the NE type or
version.
NSW
No Application Soft-
ware
Equipment
Alarm
Major
There is no application ESW installed on
the unit, or the application ESW has not
yet finished its boot process.
UIC
Unit Incompatible
Equipment
Alarm
Major
The inserted unit is not compatible with
the assigned unit.
UNAS
Unit Not Assigned
Equipment
Alarm
Warning
The unit is not assigned and cannot be
configured. To assign the unit, execute
the “Assign” command in the “Main”
function of the unit.
UNAV
Unit Not Available
Equipment
Alarm
Critical
The unit that is configured is either not
plugged or not recognized due to a fail-
ure.
PWRSVE
Battery Power Saving
Equipment
Alarm
Critical
Power saving is active on the unit, i.e. it
is kept in the “reset” state during battery
power backup.
Power saving is not supported on the
COGE5 unit.
Table 20:
AP: / unit-x, Fault Management (continued)
ID
Fault Cause
Event Type
Traffic
Affecting
Default
Severity
Description