127
15. Technical specifications
Control unit
• Mains connection fuse 10 A slow-blow; fault current circuit breaker 30 mA
• Device-internal glass tube microfuse 5x20mm 3.15AT only for the inputs and outputs
(The electronic system has an independent power supply and battery buffer)
• Mains voltage / mains frequency 230 VAC / 50 Hz
• Control unit with 1.4 m mains power supply cable and angled earthed connector
• Mains current standby (ready for operation) 17 mA (display background lighting is switched off).
• Mains current in operation 0.8 A to 1.4 A (depending on compressor size)
• Working temperature 0°C to + 40°C
• Type of protection IP 42 (IP44 when compressor is plugged in)
• Protection class 1
• Switching capacity of the relay outputs 230 V AC, 16 A, cos phi = 1
• Switching capacity of the floating contact (changeover contact) 230 Vac, 5 A ; 42 VDC 0.5 A
• Connection for serial interface COM1 via 5-pole connector (optional)
• Connection for second floating switch 230 VAC via 3 terminals (optional)
• Connection for remote signal generator 20 m line 2 x 0.75 qmm (KESSEL-No. 20162) (optional)
• Connection for compressor via earthed coupling
• Connection for valve block via Amphenol socket 6 + PE
• Dimensions [mm] = 180 x 200 x 65
• Weight control unit 1.2 kg (without packaging)
Compressor
Diaphragm compressor model EL 100
Mains voltage / mains frequency 230 VAC - 50 Hz
Connection to control unit via 1 m mains power supply
cable with straight earthed connector
Performance P = 120 W at 200 mbar
Protection class 1
Type of protection IP 44
Q = 93 l/min at 200 mbar
Working temperature 0° C up to + 40° C
Dimensions [mm] = 270 x 200 x 220
Hose connection d = 19 mm
Weight = 8.5 kg
Diaphragm compressor model EL 150
Mains voltage / mains frequency 230 VAC - 50 Hz
Connection to control unit via 1 m mains power supply
cable with straight earthed connector
Performance P = 170 W at 200 mbar
Protection class 1
Type of protection IP 44
Q = 205 l/min at 200 mbar
Working temperature 0° C up to + 40° C
Dimensions[mm] = 360 x 270 x 230
Hose connection da = 27 mm
Weight = 16 kg
Valve block with floating switch
Mains voltage / mains frequency 230 VAC - 50 Hz
Connection on the control unit via 15 m connecting line
with Amphenol connector 6 + PE
Performance P = 7W
Protection class 1
Type of protection IP 68
Working temperature 0° C up to + 40° C
Dimensions [mm] = 200 x 140 x 140
Hose connections da = 25 mm & da = 20 mm
Weight: 3,5 kg
Inno-Clean_2. Generation_3-sprachig_132Seiten:010-341 Stand 05/07 26.11.2009 12:44 Uhr Seite 127