8. Control of the septic system
8.1.System menu
Display of the hierarchy level
Time
Display of the activated floaters and their position
Display of the phase
Display of the currently expired time of the respective phase
Display of alarm/fault information
8.2.2 Incidents / faults
Display of chronological faults and incidents (see also
chapter 10 "Malfunctions and remedial measures")
All changes made to the settings are saved at this point.
8.2.3 Control type
Display of purification class, size, language and software
version
8.2.4 Maintenance deadline
Display of the next necessary and last performed main-
tenance
Note:
Data are only available if these have been stored
in the menu "Settings" by the maintenance partner. (see
also 8.3.3)
8.2.5 Water level
Pressing the OK key carries out a measurement of the
current water level in the aeration basin.
8.2.6 Parameters
Display of all set control parameters of the plant. Chan-
ging the parameters is not possible in this menu (see also
8.4.1 and 8.4.2)
8.3.1 Manual operation
Manual operation overrides automatic operation. Ma-
nual activation of the ventilation plate lifters and of the
aerator spark plug.
8.3.2 Test operation
Automatic test of the valves in the valve block. The com-
pressor is not switched on during this process.
Informationen
Wartung
Einstellungen
Systeminfo
Uhrzeit: 00:00:00
Schwimmer 1: Ein / Aus
TX:
(Phase T1 bis T24)
TX1:
(Zeit: 00:00:00)
Betriebsstunden
Ereignisse / Fehler
Steuerungstyp
Wartungstermin
Wasserhöhe
G
Parameter
8.2 Information menu
Handbetrieb
Testbetrieb
Wartungstermin
Informationen
Wartung
Einstellungen
Systeminfo
8.3 Maintenance menu
Informationen
Wartung
Einstellungen
Systeminfo
Uhrzeit: 00:00:00
Schwimmer 1: Ein / Aus
TX:
(Phase T1 bis T24)
TX1:
(Zeit: 00:00:00)
B
Informationen
Wartung
Einstellungen
Systeminfo
Uhrzeit: 00:00:00
Schwimmer 1: Ein / Aus
TX:
(Phase T1 bis T24)
TX1:
(Zeit: 00:00:00)
B
Attendend time
Events/Errors
Command type
Maintenance Date
Water level
Parameter
Information
Maintenance
Positions
Information
Maintenance
Positions
Information
Maintenance
Positions
man. operation
test operation
Maintenance Date
Time:
Floater:
T1 Feeding
System Information
Time: 00:00:00
Floater: On/Off
TX: Phase T1 - T24
TX1: (time: 00:00:00)
TX1< 00:05:54 Feeding
0
System Information
System Information
Time: 00:00:00
Floater: On/Off
TX: Phase T1 - T24
TX1: (time: 00:00:00)
System
Information